Based in Mississauga Ontario Moxie Colo has been supplying Colocation Services to it's clients since  2004

 

April 2009 Moxie Colo opened its Head Office and  a 6000sq  Data Center in Mississauga Ontario Just minutes from the 401

 

We are currently updating our Site to reflect all the changes taking place but please browse our packages and feel free to get in touch

 

If you are interested in finding out more Please contact sales@moxiecolo.com or call as at 1-866-816-6943

 


 151 Front Street Toronto Data Center

 

Open Space for up to 800sqaure feet of cabinet space

Private cages available

Top-quality, electrostatic dissipative raised floor tiles designed for 175 psf, and in some facilities

300 lbs. psf, floor load

Meet all code specifications for safety and electrical grounding, per NFPA 70

DC power and communication cabling tray pathways

Optical fiber guide conveyance system

Heavy load freight elevators or loading dock access to the space

Comprehensive and flexible cabling infrastructure

 

Security & Access

 

24/7 security management via the Security Operations Center (SOC)

Remote camera monitoring 24/7, backed by digital recordings on file for 30 days

Access to equipment area 24/7 days via card key and pass code only

Escort services 24/7 at sites with non-secured equipment areas

Locking cabinets and/or cages

Full CCTV surveillance

 

Power Infrastructure

 

200 watts per square foot including HVAC

120/208V AC and -48V DC available

Generator capacity designed to multiple 1 to 2 Mg Watt generators

Size of fuel tank 1,000 to 2,000 gallons

Generator both auto start and auto transfer. Isolation bypass feature on automatic transfer switch.

Minimum 24-hour run time fuel capacity.

Two-hour response for fuel delivery

UPS backup power

Voltage output 480 transformed to 120/208 V

-48 Volt DC Battery Plant

1200 amp expandable to 10,000 amp

2-hour battery reserve non-redundant, 4 hours redundant

"True" A/B power feeds

Grounding in accordance with NFPA 70

 


Environmental Controls

 

Under-floor cooling provided by computer-room grade equipment

Cooling not less than 200 BTU/h per square foot with an N+1 redundancy

Temperature is maintained at 72 degrees F dry bulb at ASHRAE 1%

In the event of a power interruption HVAC systems (and entire facility) operate on diesel generators

30% to 60% humidity non-condensing. Humidity control delivered through ATS/Liebert units via

infra-red humidifier

 

Interconnection Options

 

Managed Meet Me Room (MMR) to facilitate interconnection

Broad choice of leading fiber and circuit carriers in each facility

Pre-run conduit assures rapid connection to new carriers. Large number of access providers in

Buildings assures the lowest possible telecommunication link charges

Access providers are encouraged to locate muxes within  site to facilitate interconnectivity

Overhead cable trays are provided for connectivity

Layer 2 switching architecture for public interconnection and peering at select locations

24x7 diagnostic remote switch fabric and port monitoring

 

Fire Detection & Suppression

Dry-pipe pre-action sprinkler rated for telecommunication equipment/computer room

Integrated smoke/heat detector system

Under-floor leak detection system


1415 Bonhill Road Mississauga Data Center

 

6000 square feet of  cabinets

Private cages available

Mini Vaults up to 600square feet

Top-quality, electrostatic dissipative raised floor tiles designed for 175 psf, and in some facilities

300 lbs. psf, floor load

Meet all code specifications for safety and electrical grounding, per NFPA 70

Communication cabling tray pathways

Optical fiber guide conveyance system

Loading dock access to the space

Comprehensive and flexible cabling infrastructure

 

Security & Access

 

24/7 security management via the Security Operations Center (SOC)

Remote camera monitoring 24/7, backed by digital recordings on file for 60 days

Access to equipment area 24/7 days via card key only Escort services 24/7 at sites with non-secured equipment areas

Locking cabinets and/or cages

Full CCTV surveillance

 



Power Infrastructure

 

200 watts per square foot including HVAC

120/208V AC available

100% generator backup

Generator capacity 400kw

Size of fuel tank 1400 gallons

Generator both auto start and auto transfer. Isolation bypass feature on automatic transfer switch.

Minimum 24-hour run time fuel capacity.

Two-hour response for fuel delivery

UPS backup power provided by APC

Voltage output 600 transformed to 120/208 V

400 amp expandable to 1500 amp

2-hour battery reserve non-redundant, 4 hours redundant

"True" A/B/C power feeds

Grounding in accordance with NFPA 70

 



Environmental Controls

 

Under-floor cooling provided by computer-room grade equipment

Cooling not less than 200 BTU/h per square foot with an N+1 redundancy

Temperature is maintained at 72 degrees F dry bulb at ASHRAE 1%

In the event of a power interruption HVAC systems (and entire facility) operate on diesel generators

30% to 60% humidity non-condensing. Humidity control delivered through ATS/Liebert units via infra-red humidifier

 

 

Interconnection Options

 

Managed Meet Me Room (MMR) to facilitate interconnection

Broad choice of leading fiber and circuit carriers via 151 Front Stree Backhaul

Pre-run conduit assures rapid connection to new carriers. Large number of access providers in buildings assures the lowest possible telecommunication link charges

Overhead cable trays are provided for connectivity

24x7 diagnostic remote switch fabric and port monitoring

Layer 2 switching architecture for public interconnection and peering at select locations

24x7 diagnostic remote switch fabric and port monitoring

 

Fire Detection & Suppression

Dry-pipe pre-action sprinkler rated for telecommunication equipment/computer room

Integrated smoke/heat detector system

Under-floor leak detection system